Acoustiflex® PL Acoustic Pipe Lagging
A quiet environment is mandated by the Building Code of Australia for residential apartments, hotels, motels, aged care buildings, townhouses and other attached buildings. Acoustiflex® PL pipe lagging is designed to contain the intrusive noise generated by the turbulent flow of waste-water through piping and fittings.
Acoustiflex® PL pipe lagging comprises a noise barrier to contain pipe-wall vibrating noise and a high density sound absorber for the wastewater stream noise. This bonded double layer of heavyweight, but flexible acoustical material is housed within a heavy duty reinforced aluminium foil casing. Acoustiflex® PL is available with a choice of a flat or convoluted sound absorber.
Acoustiflex® PL has been rigorously tested by NATA and CSIRO laboratories and meets the requirements of the Building Code of Australia for RW ratings of 30 and 45 when correctly installed.
The flammability rating of Acoustiflex® PL,
according to AS 1530.3, is rated zero in all four indexes of ignitability, spread of flame, heat evolved and smoke developed.
The special construction of Acoustiflex® PL combines mechanical strength with exceptional flexibility offering significant time savings during installation.
Acoustiflex® PL is unaffected by water, will not delaminate and will perform continuously over the life of the building without any degradation of acoustic performance.
Products |
Copyright Acoustic Space 2006
Sound Transmission Loss (dB) for Acoustiflex PL:
0
Acoustiflex PL
Acoustiflex PL lines the Sydney World Tower
Installation
The required width of Acoustiflex® PL to go around the pipe will be given by the following formula:
W = π x (OD + [2xT]) 50 mm overlap
Where π = 3.14
OD = outside pipe diameter
T = Acoustiflex® PL thickness
Measure the diameter and total length of the pipe to be insulated.
Wrap Acoustiflex® PL around the pipe and tape with an appropriate reinforced aluminium tape (available on request).
All joints must be tightly butted and sealed in order to ensure a good seal.
Tape Spacing: 600
Tape
Pipe
length
10
20
30
40
50
60
70
125
250
500
1000
2000
4000
Frequency (Hz)
Lagged Pipe with Acoustiflex PL
Non-lagged Pipe